01 Acquire

PlantPulse Edge

The data gateway at your factory door

A full-stack industrial edge gateway that connects to PLCs and equipment over 42 industrial protocols, collects tag data, applies formula and scaling preprocessing, stores and visualizes locally, and streams upstream via a built-in OPC-UA server and MQTT/Sparkplug B. Collection, storage, time-series, dashboards, rules, and an AI copilot all fit in one container — and it runs standalone without the platform.

Key Metric

42

Industrial protocol drivers

A Capabilities · In depth

01

42 protocols, one box — including Korean and Asian lines

From Siemens S7/Profinet, Rockwell EtherNet/IP, Beckhoff ADS, and Omron FINS to Korean and Asian lines (LS ELECTRIC XGT, Mitsubishi MELSEC, Panasonic MEWTOCOL, Taiwan FATEK), Fanuc FOCAS (CNC), semiconductor SECS/GEM, and power DNP3/IEC 61850 — 42 drivers are built in. New equipment just needs a driver, and 25+ are CI-regression-tested with in-house PLC simulators.

  • 42 protocol drivers (incl. LS, MELSEC, Fanuc CNC, semiconductor SECS/GEM)
  • 3-tier architecture: in-house sockets + industrial protocol framework
  • 25+ in-house simulators for CI regression · 1,674 automated tests
42 protocols, one box — including Korean and Asian lines
02

Unify a mess of protocols into one standard — OPC-UA republish

Every tag pulled in over 42 heterogeneous protocols is re-published through a built-in OPC-UA server. SCADA and HMIs consume a single OPC-UA standard without knowing the underlying protocols. Bidirectional writes are supported — writing to a server node forwards to the actual PLC.

  • Built-in OPC-UA server — unifies 42 protocols into one standard
  • Bidirectional write forwarding · TLS (12443) · user auth
  • Compose a Unified Namespace over MQTT and Sparkplug B
Unify a mess of protocols into one standard — OPC-UA republish
03

Never lose data — store-and-forward and standalone

If the platform or a required channel drops, points queue locally up to 500,000 and drain automatically on recovery. Edge reconnects every 30 seconds and resyncs fully on recovery. With an event/time-series DB, in-memory cache, time-series engine, and dashboards built in, it collects, stores, and monitors on-site without the platform.

  • Store-and-forward buffer of 500,000 points · lossless resend
  • 30-second auto-reconnect · full resync on recovery
  • STANDALONE operation (local storage, time-series, dashboards)
Never lose data — store-and-forward and standalone
04

The edge speaks for itself — on-edge AI copilot

Ask about operations in natural language and control from the edge console. Read tools run automatically; control actions like starting/stopping OPC or writing tags are approval-gated and require human confirmation. Point it at a local LLM via an OpenAI-compatible API and data never leaves the site.

  • On-edge natural-language operations Q&A · approval-gated control (5-min TTL)
  • Point at a local LLM — retain data sovereignty
  • Multimodal image input supported
The edge speaks for itself — on-edge AI copilot
05

Gateway-level redundancy — non-stop failover

Connect two edges to a PLC's two Ethernet ports so both collect continuously, granting write authority to only one. If the writer stalls, the standby detects it via a PLC heartbeat and auto-promotes in about 8 seconds. Observation through the shared resource (PLC) makes it split-brain safe.

  • Dual independent edges · structural read HA
  • 8-second auto-failover via PLC witness
  • Split-brain safe · non-stop promotion API
Gateway-level redundancy — non-stop failover

B Architecture

Field devices · PLC · Sensors 42 industrial protocols PlantPulse Edge Drivers · Formula eval Local buffer (event/time-series DB · in-memory cache) OPC-UA server MQTT / Sparkplug B PlantPulse Platform

Collect from diverse field equipment over 42 protocols, apply formula evaluation and store-and-forward buffering, then standardize and stream upstream via a built-in OPC-UA server and MQTT/Sparkplug B. An on-edge AI copilot and HA failover fit in one box.

C Use Cases

Automotive Parts & General Manufacturing
Challenge
Mixed equipment of different makers and vintages (LS, MELSEC, Siemens) makes collection hard to standardize.
Solution
Collect heterogeneous equipment through one gateway with 42 drivers and standardize via OPC-UA.

Outcome

Unified collection · minimal integration development

Semiconductor & Electronics
Challenge
Fab equipment must connect via standards and no subtle signal can be missed.
Solution
Connect equipment directly with the semiconductor SECS/GEM standard and preprocess at high speed on the edge.

Outcome

Standard equipment connection · high-frequency capture

Defense & Power
Challenge
Operate in air-gapped networks with no data exfiltration, and need power standards (DNP3/IEC 61850).
Solution
Air-gapped offline install and image signing, power protocol drivers, and local-LLM AI keep data sovereign.

Outcome

Full air-gapped operation · zero data exfiltration

E More Capabilities

01

42 protocol drivers

Connect to virtually any equipment — S7, EtherNet/IP, MELSEC, LS, FINS, FOCAS, SECS/GEM, DNP3, IEC 61850.

02

OPC-UA republish

Re-publish 42 protocols' tags as one OPC-UA standard. Bidirectional write, TLS, and auth supported.

03

MQTT · Sparkplug B · UNS

Compose a Unified Namespace with a built-in MQTT broker and full-lifecycle Sparkplug B publishing.

04

Store-and-forward · standalone

500,000-point buffering, 30-second auto-reconnect, and platform-free STANDALONE operation.

05

Formula & scaling preprocessing

Compute formula evaluation, unit conversion, deadband, and derived tags at collection time for better quality.

06

On-edge AI · HA · security

Approval-gated on-edge AI copilot, 8-second PLC-witness failover, end-to-end TLS, image signing, and air-gap.

F Technical Specifications

Protocols
42 drivers (S7, EtherNet/IP, MELSEC, LS, FINS, FOCAS, SECS/GEM, DNP3, IEC 61850…)
Standards · UNS
OPC-UA server (12000/12443) · MQTT (1883/1884) · Sparkplug B
Resilience
Store-and-forward 500,000 points · 30-sec auto-reconnect · STANDALONE
AI · HA
On-edge AI copilot (approval-gated control) · 8-sec PLC-witness failover
Built-in stack
Event/time-series DB · in-memory cache · time-series engine & dashboards · no-code flows
Deployment · security
One-line install · OTA (auto-rollback) · air-gap · Cosign signing · end-to-end TLS
Quality
1,674 automated tests · 25+ simulator CI verification · EN/KO

G Product Screens

PlantPulse Edge — The data gateway at your factory door

D FAQ

Do you support our plant's equipment protocols?

42 drivers are built in — S7, EtherNet/IP, MELSEC, LS, FINS, ADS, FOCAS (CNC), SECS/GEM (semiconductor), DNP3, IEC 61850 (power) and more. Coverage extends broadly to Korean and Asian lines, and protocols not on the list can be added.

Can I unify multiple protocols into one?

Yes. Every tag collected over 42 protocols is re-published through the built-in OPC-UA server, so SCADA and HMIs consume a single OPC-UA standard. You can also compose a Unified Namespace over MQTT and Sparkplug B.

Our network drops often — will data be lost?

Store-and-forward buffers up to 500,000 points locally and resends automatically on recovery, so nothing is lost. It reconnects every 30 seconds and resyncs fully on recovery.

Does it work in air-gapped networks?

Yes. Signed offline install bundles let you install and operate without internet, and the on-edge AI can point at a local LLM so data never leaves the site — ideal for security-first defense and power sites.

Can I make the gateway itself redundant?

Connect two edges to a PLC's two ports for structural read HA, with automatic failover in about 8 seconds via a PLC witness. Observation through the shared resource makes it split-brain safe.

See it live on real operating screens